 High-Speed Refrigerated Centrifuges

CR22GII |

CR21GII |
High efficiency, too. From the high-torque brushless motor and powerful refrigeration to automatic rotor identification and other time-saving automated functions, these relatively compact units deliver. Optional high-capacity lightweight rotors are easier to transport and load, and they reduce acceleration and deceleration times beyond those achieved by the powerful motor alone. |
Features
Easy operation
- Movable liquid-crystal panel
- RCF calculation and display
- Pre-cooling
- Rotor database update function
- CE marking qualified
- Net run-time input
Advanced technology
- PWM (Pulse Width Modulation) motor control
- Automatic rotor identification
- Non-contact imbalance protection
- User lockout system
- "Rotor Quick Setting System" only requires placing the rotor on the drive shaft
 Specifications
| Maximum speed (rpm) |
22,000
|
21,000
|
| Maximum RCF (x g) |
55,200 (R22A4 rotor)
|
50,300 (R22A4 rotor)
|
| Maximum capacity (tubes x ml) |
1,000 x 4 (R9A rotor)
|
| Maximum speed at maximum-capacity rotor and maximum RCF |
9,000 rpm, 15,300 x g
|
| Drive motor |
High-torque brushless high-frequency motor
|
| Speed control range (rpm) |
300 to 22,000
|
300 to 21,000
|
| Temperature range adjustment (°C) |
-20 to +40
|
| Timer |
One second to 99 minutes and 59 seconds, with a HOLD function
(one minute to 99 hours and 59 minutes optional)
|
| Refrigerator capacity/refrigerant |
1.5kW/R404a
|
| Function |
Memory-based programmed operation |
30 programmed operations possible |
| Acceleration/deceleration time variable |
Nine-stage variable acceleration, nine-stage braked deceleration, plus free deceleration |
| RCF calculation |
 |
| RCF integrator |
 |
| RTC (real-time control)* |
 |
| Over-speed detector |
 |
| Rotor stoppage buzzer |
 |
| Imbalance detection device |
 |
| Automatic rotor temperature compensation |
 |
| Self-diagnosis |
 |
| Automatic rotor identification |
 |
| User lockout system |
 |
| Variable deceleration function |
 |
|
| Vertical rotor |
Available |
| Continuous flow rotor |
Available |
| Power requirements |
Single phase, AC 220/230/240V±10%, 30A, 50/60Hz
|
| Dimensions (mm) |
752 (W) x 810 (D) x 994 (H/Panel closed) / 1,144 (H/panel opened) / hight to table is 858
|
| Standard accessories |
Instruction manual, rotor cleaning bar, silicone grease |
| Weight (kg) |
300
|
Notes:
- *The start and end of revolution can be controlled by inputting their time and date. This is the same function as the RTC of the CP-WX/CP-MX/CS-GXL series ultracentrifuge.
- The CR-GII series centrifuges must be operated with the automatically identifiable rotors in order to confirm to the CE marking requirments. The following rotors are not equipped with the automatically identification function. When using these rotors, please place an order the CR-GII series centrifuges that are not conforming to the CE marking requirements. R18C, R13C and R10C continuous flow rotors. For further information, please contact your Hitachi distributors.
Cautions during installation
- To optimize the heat exchange efficiency of the refrigerator unit, install in a space according to the specifications.
- Install on a stable floor.
- Avoid installation near equipment that could be a heat source, or in direct sunlight.
- An extension cord should not be used.
- The heat radiation rate of the centrifuge is about 2.3 kw (about 2,000 kcal/h).
- As a safety precaution, ground the equipment properly according to applicable electrical codes.
|
|
|

|