Hitachi Koki HITACHI
HomePower ToolsLife scienceFinancialCorprate ProfileContact us Japanese

Home > Application


Application

No. Preparative Ultracentrifuge, No. Micro Ultracentrifuge,
No. High-Speed Refrigerated Centrifuge, No. ETC

No. Subject Model Sample
Name
Separation
method
134 Separation of ink using micro ultracentrifuge CS-GXL series / S140AT Ink Density-gradient centrifugation
133 Purification of plasmid DNA using S-cap and ultracentrifuge CP-WX series / P70AT2 plasmid DNA Isopycnic separation
132 Separation and purification of hepatitis B antigens using a zonal rotor - (3) CP-WX series / P35ZT Hepatitis B antigens Density-gradient centrifugation
131 Separation and purification of hepatitis B antigens using a zonal rotor - (2) CP-WX series / P35ZT Hepatitis B antigens Density-gradient centrifugation
130 Separation and purification of hepatitis B antigens using a zonal rotor - (1) CP-WX series / P35ZT Hepatitis B antigens Density-gradient centrifugation
129 Purification of single-walled carbon nanotubes by means of an ultracentrifuge CS-GXL series / S52ST Carbon nanotubes Density-gradient centrifugation
127 Centrifugation by means of micro tubes and a new rotor designed for micro ultracentrifuges CS150/120GXL Rice dwarf virus Pelleting
126 Concentration of protein solution by means of T15A38 fixed angle rotor CF16RX/15RX
T15A38
Protein solution Ultrafiltration
(Microcon)
125 Concentration of protein solution by means of ultrafiltration tubes CF16RX/12RX/9RX
T6AP31
Protein solution Ultrafiltration
(Ultra-4)
124 Very efficient collection of sediment by means of the wide-mouth 1 L bottle CR-G series Fine powder dispersed water Differential pelleting centrifugation
123 Reliable separation of cell membranes by means of 50-ml conical tube CR-G series Cell membranes Density gradient centrifugation
122 Experiment on Percoll? density gradient centrifugation by means of 50-ml conical tubes CR-G series Organelles Isopycnic centrifugation
112 Separation of cell organelle by means of a new-model fixed angle rotor S55A Organelle Differential pelleting
centrifugation
111 Pelleting by means of a new-model fixed angle rotor S55A Organelle Differential pelleting
centrifugation
110 Separation of cell organelle using easily prepared density gradient of Nycodenz P28S Organelle Density gradient
centrifugation
109 Easy preparation of density gradient using Nycodenz P55ST2 Organelle Density gradient
centrifugation
108 Separation of liver homogenate using the swinging bucket rotor for 5-ml tubes and the new-model micro ultracentrifuge S52ST Organelle Density gradient
centrifugation
106 Separation of Rotavirus by means of a micro ultracentrifuge CS150/120GXL
S80AT3
Rotavirus Pelleting
105 Separation of small range structured virus (SRSV) by means of a micro ultracentrifuge CS150/120GXL
S80AT3
Small range structured virus Pelleting
104 Separation of SRSV with a swinging bucket rotor (5 ml x 4 tubes) in the new micro ultracentrifuge S52ST Small range structured virus Pelleting
103 Separation of lipoprotein from serum with the new micro ultracentrifuge at million x g S140AT Lipoprotein Differential floating separat
101 Separation and fractionation of proteins and complexes by means of an ultracentrifuge using a density-gradient solution prepared by the DGF-U fractionator P28S2 Triton extracted from culture nervous tissues Rate-zonal separation
97 Purification of DNA sequencing samples after the cycle sequence operation using the R10H microplate rotor for high-speed refrigerated centrifuges R10H Purification of DNA sequencing samples High speed micro-plate centrifugation
96 Purification of a PCR product using a microplate with the R10H horizontal rotor for high-speed refrigerated centrifuges R10H Purification of a PCR product High speed micro-plate centrifugation
90 Quick separation of lipoprotein with the neo angle rotor S100NT Lipoprotein Floating equilibrium separation
89 Separation of lipoprotein from human serum with the preparative micro ultracentrifuge S80AT3 Lipoprotein Differential floating separat
88 Examination of centrifugation time when using a carbon fiber rotor that can accommodate six 1-liter bottles R7AF2 E.coli. Pelleting
87 Collection of DNA by ethanol precipitation using a swing rotor capable of being used with microplates R6S DNA
(λ/Hind III)
Pelleting
86 Separation of cell culture solution using the carbon fiber rotors that can accommodate four 1-liter bottles R9AF E.coli. Pelleting
85 Separation of plasmid DNA with 8ml tube S80AT3 Plasmid DNA Step mode
operation
84 Separation of plasmid DNA with 8ml tube S80AT3 Plasmid DNA Isopycnic separation
82 Separation of plasmid DNA using micro-ultracentrifuge S140NT Plasmid DNA Isopycnic separation
81 Separation of serum lipoprotein using micro-ultracentrifuge S150AT Lipoprotein Differential floating separat
80 Separation of plasmid DNA using micro-ultracentrifuge S150AT Plasmid DNA Step mode
operation
77 Separation of total RNAs from homogenated cell line with neo-angle rotor S100NT RNA of cell line Pelleting
76 Separation of total RNAs from homogenated cell line with fixed-angle rotor S150AT RNA of cell line Pelleting
70 Separation of type S1 Lipoprotein (a) by ultracentrifuge P100AT Lipoprotein Differential floating separat
69 Separation of lipoprotein and electrophoresis P100AT Lipoprotein Differential floating separat
64 Preparative Micro-Ultracentrifuge CS-GX series S120AT3 Lipoprotein Differential floating separat
62 Separation of chloroplast DNA S100AT5 Chloroplast DNA Isopycnic separation
61 Separation of chloroplast P28S Chloroplast Density gradient
centrifugation
60 Separation of plasmid DNA by neo-angle rotor RP120NT Lasmid DNA Step mode operation
59 Separation of plasmid DNA by neo-angle rotor RP120NT Plasmid DNA Iopycnic separation
57 Separation of lipoprotein P100AT Lipoprotein Differential floating separation

page top

Terms of Use, etc.
Hitachi Koki Co., Ltd. Copyright(C) 2000-2006 Hitachi Koki Co., Ltd All rights reserved .